Radiation and RF Shielding

Radiation shielding for imaging, nuclear medicine and radiotherapy rooms, and RF shielding for MRI.

We design the shielding of the rooms in a hospital that hold a source of ionising radiation or a magnetic resonance scanner: the radiography, fluoroscopy, CT, mammography and dental rooms, the catheterisation and interventional laboratories, nuclear medicine and PET/CT with their hot laboratories, the radiotherapy bunkers, and the MRI rooms with their RF enclosures. The shielding is part of the architecture and the structure, so we design it with them, and with the building services that must pass through it.

Each design starts from the room's equipment and workload and from the use of the spaces around it, above it and below it. We calculate the barriers to NCRP Reports 147 and 151, or to the method agreed with the hospital's medical physicist, so that the dose in each neighbouring space stays within its design goal, and we draw the lead, the concrete, the doors and the viewing windows that make up the shield, with every joint, frame and penetration detailed so that it keeps the shield's lead equivalence.

We prepare the shielding report a licence application needs, for the Federal Authority for Nuclear Regulation in the UAE or the radiation authority of the country, and specify the shielding for the specialist contractor who supplies and builds it. Where the client wants it, we monitor the installation on site, inspect each layer before it is covered, and witness the radiation survey and the RF attenuation test that confirm the shielding before the equipment is taken into use.

X-ray, nuclear medicine and radiotherapy rooms

In diagnostic and interventional rooms the shield is usually lead: sheet lead laminated to plasterboard on the walls, lead-lined doors and frames, and lead glass in the viewing window to the control room, each of the lead equivalence the calculation gives, commonly 1.5 to 3 mm. We design to the goals of NCRP Report 147, an air kerma of 0.1 mGy a week in controlled areas and 0.02 mGy in uncontrolled ones, and lap every joint and line every box and penetration so that the shield is continuous.

The 511 keV photons of PET need thicker lead or concrete, which we calculate to AAPM Task Group 108, for the uptake rooms, the scanner and the hot laboratory. Radiotherapy bunkers for linear accelerators are mass concrete at a density of 2.35 tonnes per cubic metre, with primary barriers commonly 1.5 to 2.5 m thick depending on the energy, a maze that brings the dose at the entrance down, and above 10 MV a door with borated polyethylene against the neutrons the beam produces, all to NCRP Report 151.

MRI rooms and RF enclosures

An MRI room is shielded the other way round: the RF enclosure keeps out the radio frequencies that would spoil the image, while the magnet's own shielding, with steel where needed, keeps its field in. We design the RF enclosure as a continuous shell of copper or galvanised steel panels on the walls, the floor and the ceiling, isolated from the building's structure and earthed at a single point, with an RF door and an RF window, for an attenuation of 100 dB or more across the scanner's frequencies, tested to IEEE 299.

Every service that enters the room passes through the shield in a form that keeps it whole: air through honeycomb waveguide vents, pipes and medical gases through waveguides, power and signal cables through the filters of the penetration panel, and the quench pipe that vents the magnet's helium outside. Where the fringe field would reach beyond the room, we add steel magnetic shielding so that the 0.5 mT line stays inside, and plan the zones of the ACR Manual on MR Safety around it.

Shielding we design

Diagnostic and interventional rooms

  • Radiography, fluoroscopy and mammography rooms: lead-lined walls, doors and viewing windows
  • CT rooms: lead equivalence calculated for the scanner's workload and the spaces around it
  • Catheterisation and interventional laboratories: the procedure room with its control and equipment rooms
  • Dental and small X-ray rooms: lead-lined partitions and doors for the unit

Nuclear medicine and PET

  • Gamma camera and SPECT rooms: lead or concrete for the isotopes in use
  • PET and PET/CT: barriers for 511 keV photons around the uptake rooms and the scanner
  • Hot laboratories and waste stores: shielded rooms for dispensing radiopharmaceuticals and holding their waste

Radiotherapy

  • Linear accelerator bunkers: primary and secondary barriers in mass or high-density concrete
  • Mazes and doors: the maze geometry and, above 10 MV, neutron-shielded doors
  • Brachytherapy rooms: shielding for high dose rate afterloaders
  • Penetrations: ducts, pipes and cables carried through the barriers on offset paths

MRI rooms

  • RF enclosures: copper or galvanised steel shells with an RF door and window
  • Penetration panels: filters for power and signal cables, waveguides for pipes and gases
  • Honeycomb vents: waveguide vents for the supply and extract air
  • Magnetic shielding: steel shielding that keeps the 0.5 mT line inside the room
  • Quench pipes: the vent that carries the magnet's helium out of the building

Standards we work to

  • NCRP Report 147: structural shielding design for medical X-ray imaging facilities
  • NCRP Report 151: structural shielding design and evaluation for megavoltage X- and gamma-ray radiotherapy facilities
  • AAPM Task Group 108: PET and PET/CT shielding requirements
  • IAEA GSR Part 3: radiation protection and safety of radiation sources, the international basic safety standards
  • IEC 61331-1: protective devices against diagnostic medical X-radiation, the attenuation properties of materials
  • IEEE 299: measuring the effectiveness of electromagnetic shielding enclosures
  • ACR Manual on MR Safety: the zones and the screening of an MRI suite
  • The radiation safety regulations of the UAE's Federal Authority for Nuclear Regulation