Skip to the content
Lift cars in an atrium under a glass roof, seen from below

Vertical Transportation

Passenger, bed and firefighters lifts, escalators and moving walks, designed from the traffic they carry.

We design the vertical transportation of buildings: passenger lifts, the bed lifts and goods lifts of hospitals, firefighters lifts and evacuation lifts, service lifts, escalators and moving walks. We analyse the traffic, choose the number, size, speed and grouping of the lifts, and coordinate their shafts, pits, machine rooms, power supplies and fire protection with the architecture, the structure and the building services.

The design starts from the people and goods the building moves, and when. For an office we calculate the handling capacity, the share of the building's population the lifts carry in its busiest 5 minutes, and the interval or the waiting time, to CIBSE Guide D, by calculation or by simulation. For a hospital we separate the flows of patients on beds, visitors, staff, goods and waste, give each the lifts its volume calls for, and design the supply of the bed lifts and evacuation lifts from the standby generators with the electrical design.

We specify the lifts to EN 81-20 and EN 81-50, and the escalators and moving walks to EN 115-1, or all of them to ASME A17.1, with their energy performance to ISO 25745, for the lift contractor who supplies, installs and maintains them, and we review its drawings and calculations against the design. Where the client wants it, we monitor the installation on site, check the shafts and pits before the lift contractor starts, and witness the tests and the inspection by an independent inspector before the lifts are taken into use.

Traffic and the design of lifts

We size each group of lifts for its building's peak: the morning up-peak of an office, or its lunchtime peak where that is heavier, to the handling capacity and the interval CIBSE Guide D gives for its use. Tall buildings are divided into zones, each served by a group of its own, and destination control assigns passengers to cars by their floor before they board. The car sizes follow ISO 4190-1, the speeds rise with the travel, and we design the public lifts to EN 81-70, with cars of at least 1,100 by 1,400 mm that take a wheelchair user and a companion.

Traction lifts without a machine room, the machine in the head of the shaft, serve most buildings; traction lifts with a machine room above the shaft serve the heaviest and fastest duties, and hydraulic lifts short travels and heavy goods. We give each shaft its pit, its headroom and the refuge spaces of EN 81-20, its ventilation, and the fire resistance the fire strategy requires, with landing doors tested to EN 81-58.

Bed lifts, firefighters lifts and escalators

A hospital's bed lifts carry a bed with its patient, the staff and the equipment that go with it. We size their cars to the healthcare class, class III, of ISO 4190-1, commonly 2,000 kg with a car of 1,500 by 2,700 mm, or 2,500 kg with 1,800 by 2,700 mm where an intensive care bed travels with its equipment, with doors wide enough for the bed and a car that levels exactly at every floor, so that no wheel catches at the sill.

Firefighters lifts follow EN 81-72: a car of at least 630 kg and 1,100 by 1,400 mm that reaches the furthest floor from the fire service access level within 60 s, in a protected shaft; EN 81-73 sets how every other lift returns to its designated floor on the fire alarm. Escalators to EN 115-1 rise at no more than 30°, or 35° where the rise is no more than 6 m and the speed no more than 0.5 m/s, and moving walks at no more than 12°, for airports, stations and malls.

Lifts and escalators we design

Passenger lifts

  • Office and residential groups: sized by traffic analysis to CIBSE Guide D
  • Destination control: passengers assigned to cars by their floor before they board
  • Accessible lifts: cars to EN 81-70 for wheelchair users and their companions
  • Traction lifts without a machine room: the machine in the head of the shaft, for most buildings

Hospital lifts

  • Bed lifts: cars to class III of ISO 4190-1, on the essential supply
  • Evacuation lifts: for patients who cannot use the stairs, on the essential supply
  • Goods and service lifts: for supplies, meals and waste, apart from the patients
  • Priority service: a call that brings a bed lift to the emergency team

Fire and safety

  • Firefighters lifts: to EN 81-72, in protected shafts
  • Fire recall: every other lift returned to its designated floor on the fire alarm, to EN 81-73
  • Seismic measures: to EN 81-77 or ASME A17.1 where the site's earthquakes require them

Airports, stations and malls

  • Escalators: to EN 115-1, at no more than 30°, or 35° on short rises
  • Moving walks: level or inclined at no more than 12°, for the long distances of terminals
  • Energy performance: classified to ISO 25745, with escalators and walks that slow or stop when no one is on them

Building coordination

  • Shafts and pits: headroom and refuge spaces to EN 81-20, coordinated with the structure
  • Machine rooms: above the shaft for the heaviest and fastest lifts, ventilated for their heat
  • Power and controls: supplies from the essential distribution, and links to the fire alarm and the building management system

Standards we work to

  • EN 81-20 and EN 81-50: the construction and installation of lifts, and the design rules and tests of their components
  • EN 81-70: accessibility to lifts for persons including persons with disability
  • EN 81-72 and EN 81-73: firefighters lifts, and the behaviour of lifts in the event of fire
  • EN 115-1: the safety of escalators and moving walks
  • ASME A17.1: the safety code for elevators and escalators
  • ISO 4190-1: lift installation, class I, II, III and VI lifts
  • CIBSE Guide D: transportation systems in buildings
  • The local authority codes of the UAE, the UAE Fire and Life Safety Code of Practice among them